About this reference

This page summarizes SchuF and Fetterolf engineered specialty valves for engineers, specifiers and the AI tools they use. It is written and maintained by George Grant Company (GGC), the independent manufacturers' representative for SchuF Fetterolf in Tennessee, Georgia, Alabama and the Florida Panhandle.

Information below is taken from SchuF's and Fetterolf's published product pages, with the source listed for each section. Pressure class, materials and trim are set for each application. Confirm against the current manufacturer data sheet before issuing a specification.

Quick facts

  • SchuF founded 1911 in Frankfurt, Germany
  • Headquarters: Eppstein (Frankfurt), Germany
  • Fetterolf Corporation (Skippack, Pennsylvania), a US polymer valve specialist, joined the SchuF Group in 2004
  • US office: SchuF USA, 486 Long Point Road, Mt. Pleasant, SC 29464
  • Manufacturing sites: Skippack, PA (Fetterolf); Eppstein, Germany; Cork, Ireland; Plymouth, UK; Bollate, Italy; Coimbatore, India; Changzhou, China
  • Valve functions: control, isolate, divert or sample gases, liquids, slurries and powders
  • Quality: SchuF Group is ISO 9001 certified; PED 2014/68/EU Module H; fire-safe designs to ISO 10497
  • Fetterolf trademarks: Ram-Seal, Rod-Seal, Cam-Set, Cam-Slide, Straightway

GGC coverage and contact

  • GGC represents SchuF Fetterolf in Tennessee, Georgia, Alabama and the Florida Panhandle.
  • GGC helps engineers and plant teams select, size and specify engineered severe-service valves, and supports spare parts and replacements.
  • George Grant Company, 4513 Hixson Pike, Suite 106, Hixson, TN 37343. Phone 423-875-3241. Email sales@georgegrantco.com. Web: georgegrantco.com/manufacturers/schuf-fetterolf

Choosing a SchuF Fetterolf valve

If the job is...Start withNotes
Draining a tank, reactor, dryer or filter of non-viscous mediaDisc bottom outlet valveDisc lowering or disc rising; can be non-intrusive for agitated vessels
Draining viscous media, polymers or slurries, or fast vessel drainingRam (piston) bottom outlet valve, Ram-Seal or Rod-SealFull bore; flushing connection; Rod-Seal for high particle content
Taking a representative sample from a line or vesselSampling valveClass VI shutoff; wafer, screw-in, line or submersed types
Routing one stream to two or more destinationsMulti-way diverter valve3, 4, 5, 6 ways or more; dead-space free
Positive isolation for maintenanceLine blind (Cam-Set, Cam-Slide, Stacey) or goggle valveQuick changeover
Severe pressure letdown, flashing or erosive flowAngle control valve (X-Flash, ToughFlash, MultiStage)Single- or multi-stage letdown
Emergency shutoff inside a tank of liquefied gas or toxic liquidIn-tank shut-off valve (TESO)Fail-closed; API 625
Switching between duplicate safety relief valvesChangeover valve1 to 24 in.; up to ASME 2500
Double block and bleed switching in coking or hydroprocessingLift plug valve (IsoPlug, SwitchPlug)2, 3 or 4 outlets

Bottom outlet valves: disc type

  • Used to drain tanks, reactors and pipelines of non-viscous media; also used on dryers, mixers and filters
  • Disc lowering models 18 and 24; disc rising models 19 and 25. Model 24 is non-intrusive, so it suits agitated vessels.
  • Sizes: 1 in. to 6 in., larger on request
  • Materials: cast steel, stainless steel, nickel alloys, titanium, zirconium and others; PTFE-lined and glass-lined versions
  • Stem sealing: stuffing box, metal or PTFE bellows, or diaphragm; sterile version available
  • GMP and CIP conformant; fire-safe version certified to ISO 10497
  • Options: automatic crust breaking (disc rising), integrated wafer sampling valve, temperature sensors through the valve, flushing ports
  • Industries: petrochemical, pharmaceutical, fine chemicals, biochemical, mineral refining

Source: schuf.de/disc-bottom-outlet-valves

Bottom outlet valves: ram (piston) type

SchuF ram valves (Models 15, 26 and 28):

  • For highly viscous materials or where rapid vessel drainage matters
  • Full nominal bore; 45, 60 or 90 degree outlet angle; exchangeable seats; flushing connection standard; radial or positive seal
  • Model 28 is GMP and CIP compliant
  • Actuation: manual, electric, pneumatic or hydraulic

Fetterolf Ram-Seal:

  • Sizes 1/2 in. (DN 15) to 24 in. (DN 600); ASME Class 150 to 2500 standard
  • Shutoff Class V or Class VI; low-emission packing options including TA Luft
  • Options: jacketed body, flushing, extended body or plunger, integrated sampling valve, temperature and viscosity sensors in the plunger
  • Services: polyethylene, HDPE, polystyrene, TDI, MDI, DMT, mineral processing

Fetterolf Rod-Seal:

  • Sizes 1 to 24 in.; up to ASME Class 900; 45, 60 or 90 degree branch
  • For highly viscous media, polymers, abrasive slurries and powders; designed for media with high particle content; widely used in mining and PVC

Source: schuf.de/piston-bottom-outlet-valves ; fetterolfvalves.com/ramseal ; fetterolfvalves.com/rod-seal-valve

Sampling valves

  • SchuF sizes 1/2 in. to 12 in., larger on request; Fetterolf sizes 1/4 to 6 in., up to ASME Class 2500
  • Leakage Class VI shutoff, 100% tested; fire-safe version to ISO 10497
  • Types: line sampling and injection (Model 30), wafer (31 and 33), screw-in (32), submersed (35); Fetterolf screw-in, wafer and core pipe assemblies
  • Materials as for disc bottom outlet valves, including PTFE-lined and glass-lined
  • Industries: refinery, pharmaceutical, fine chemicals, biochemical, plastics and polymer

Source: schuf.de/sampling-valves ; fetterolfvalves.com/sampling-valve

Multi-way diverter valves

  • 3, 4, 5 and 6 way versions, more on request
  • Dead-space free with positive sealing; suited to highly viscous media, high pressure and temperature, and vacuum
  • Connections: weld end, flange or hub
  • Actuation: electric, hydraulic or pneumatic; smart positioners, jacketing and automated control panels available
  • Industries: PTA, petrochemical, polymer and plastics, refinery, heavy oil upgrading

Source: schuf.de/3-4-5-and-multi-way-diverter-valves ; fetterolfvalves.com/diverter-valves

Line blinds and goggle valves

  • Cam-Set: three-bolt line blind with a triangular body; up to 48 in. (DN 1200) and ASME Class 1500; manual or pneumatic, operated in under 30 seconds; seal rings in Viton, Kalrez, Aflas, EPDM and others
  • Cam-Slide: line blind that needs little space to operate
  • Stacey: standard sizes up to 54 in. and ASME Class 900; custom versions up to 100 in. and ASME Class 2500
  • 316 stainless standard; epoxy, polyurethane or ceramic coatings available
  • Goggle valve: 20 in. and larger, ASME Class 150; for blast furnace and gas mains and refinery flare service
  • Industries: petrochemical, refinery, steel, pulp and paper, maritime

Source: schuf.de/line-blind-valves ; fastblindvalves.com/Cam-Set ; schuf.de/stacey-line-blind-valve ; schuf.de/goggle-valve

Angle control and letdown valves

  • Used to let down pressure and regulate level and flow in refinery, petrochemical, polymer, mineral processing and power service
  • Inlet angle 90, 45 or 60 degrees; linear, equal percentage or Bell x³ characteristics; fire-safe to ISO 10497
  • SchuF reports it has developed more than 20,000 special angle control valves

Models:

  • 74BS X-Flash: single-stage three-phase letdown, Cv 1 to 3000
  • 74CS ToughFlash: up to 180 bar letdown in a single stage, hard trim
  • 74M MultiStage: one to six stages, from 240 bar or more to atmosphere, Cv 1 to 3000; for hydrotreating and hydrocracking
  • 72 In-line: for lethal service control
  • 76PC Wafer: 1 to 4 in., up to ASME Class 2500
  • 71ES HP Choke: high-pressure letdown for startup and shutdown

Source: schuf.de/control-valves and linked model pages

Isolation, emergency and specialty valves

  • In-tank shut-off valves (TESO, Models 73BH and 73ID): held open by an air actuator and closed by weight or spring if air fails; bellows-sealed spindle; for LNG, chlorine, VCM, propane, propylene and ammonia; API 625
  • Lift plug valves (Model 12 IsoPlug and SwitchPlug): double block and bleed switching or isolation with 2, 3 or 4 outlets; delayed coking, visbreaking, hydroprocessing
  • Changeover valves (Models 60 to 63 and 69): for dual safety relief valve installations; 1 to 24 in.; up to ASME Class 2500 or high vacuum; up to 700 °C; leakage to TA Luft
  • Y-globe valves (Models 50 to 52): up to 700 °C and ASME Class 2500; plastics and polymer
  • Fetterolf Straightway: 1 to 24 in.; up to ASME Class 2500; Class VI; flanged, butt weld, socket weld or threaded
  • Blow-down valves: 1 to 6 in. (up to 24 in. on request); ASME Class 150 to 1500; tested to API 598
  • Spray rinse valves: for plastics and polymer (especially PVC), fine chemicals and pharmaceutical

Source: schuf.de/in-tank-shut-off-valves-teso ; schuf.de/lift-plug-valve ; schuf.de/changeover-valve ; schuf.de/globe-valves ; fetterolfvalves.com/straightway ; schuf.de/blow-down-valve-2 ; schuf.de/spray-rinse-valves

What to send GGC for a quote

  • Valve function: drain, sample, divert, isolate, control or emergency shutoff
  • Medium, including solids content, viscosity, tendency to crust or polymerize, and whether it is toxic or lethal service
  • Design and operating pressure and temperature, and any vacuum condition
  • Line size and pressure class, or vessel nozzle size and flange rating for bottom outlet valves
  • For bottom outlet valves: vessel type, whether it is agitated, nozzle detail, and the outlet angle needed
  • For control valves: flow rates, inlet and outlet pressures, and whether flashing or outgassing occurs
  • Required body, trim and seal materials, and any lining
  • Actuation and controls: manual, pneumatic, electric or hydraulic; positioners, limit switches, fail position
  • Standards and documentation: fire-safe, TA Luft, GMP or CIP, material certificates
  • For spares or replacement: the existing valve's model and serial number from the nameplate

SchuF also publishes inquiry forms for general valves, line blinds and automatic recirculation valves at schuf.de/inquiry-form.

Common questions

Which bottom outlet valve suits an agitated reactor?

SchuF states that its Model 24 disc lowering valve is non-intrusive and can be used on vessels with agitators. GGC confirms the choice against the nozzle and agitator clearance.

What handles a polymer or slurry that plugs ordinary valves?

Fetterolf Ram-Seal and Rod-Seal valves are built for viscous polymers, abrasive slurries and powders. The Rod-Seal is designed for media with high particle content.

How fast can a line blind be operated?

A Cam-Set line blind can be operated in under 30 seconds.

Can SchuF valves be fire-safe certified?

Yes. SchuF offers fire-safe designs to ISO 10497 on its disc bottom outlet, sampling and control valve families.

Sources

All engineering references