About this reference

This page summarizes McCrometer flow meter technologies for engineers, specifiers and the AI tools they use. It is written and maintained by George Grant Company (GGC), McCrometer's independent manufacturers' representative for industrial and oil and gas applications in Tennessee, Georgia, Alabama, the Florida Panhandle, Mississippi and Arkansas.

Specifications below are taken from McCrometer's published product pages and specification sheets, with the source listed for each section. Final ratings for any meter come from McCrometer's sizing for the specific application. Always confirm against the current manufacturer data sheet before issuing a specification.

Quick facts

  • Manufacturer: McCrometer, Inc., 3255 West Stetson Avenue, Hemet, California 92545, USA
  • In business since: 1955
  • Parent company: Veralto (McCrometer is a Veralto Water Quality company)
  • Calibration: two California facilities that test meters from 1/2 in. to 72 in.; NVLAP accredited calibration laboratory (Lab Code 201023-0); ISO 17025 accreditation
  • Quality system: ISO 9001:2015
  • Technologies covered here: V-Cone and Wafer-Cone differential pressure meters; Ultra Mag full-bore electromagnetic meters; FPI Mag and SPI Mag insertion electromagnetic meters; McPropeller propeller meters

GGC coverage and contact

  • GGC represents McCrometer for industrial and oil and gas applications in Tennessee, Georgia, Alabama, the Florida Panhandle, Mississippi and Arkansas.
  • Municipal water and wastewater projects are served by McCrometer's separate municipal representatives. Landfill gas and RNG projects, including county- and authority-owned landfills, are handled by GGC.
  • GGC helps with technology selection, sizing, configuration checks (conductivity, temperature, hot tap and straight run), specification review and replacements. For a replacement, send the existing tag or model number.
  • George Grant Company, 4513 Hixson Pike, Suite 106, Hixson, TN 37343. Phone 423-875-3241. Email sales@georgegrantco.com. Web: georgegrantco.com/manufacturers/mccrometer

Choosing a McCrometer technology

If the application is...Start withWhy
Steam, gas, wet or dirty gas, or a liquid with little straight runV-ConeDifferential pressure meter that conditions its own flow profile; typically 0 to 3 diameters upstream and 0 to 1 downstream
Gas or liquid in a 1 to 6 in. line where a flangeless meter fits between existing flangesWafer-ConeWafer-style cone meter with interchangeable cones
Conductive liquid, slurry or sludge in a new or replaceable spool, 1.5 to 48 in.Ultra MagFull-bore mag with no obstruction and no moving parts
Large clean-water main (cooling, chilled, condenser, process water) that cannot be shut downFPI MagMulti-electrode insertion mag installed by hot tap
Lower-cost insertion measurement where about ±2% is acceptableSPI MagSingle-point insertion mag installed through a ball valve or corporation stop
Industrial water, fire water or chemical injection without external powerMcPropellerMechanical propeller meter with magnetically coupled register

Electromagnetic meters require a conductive liquid (minimum 5 µS/cm on the Ultra Mag and FPI Mag). They do not measure gas, steam or hydrocarbons; use the V-Cone for those.

V-Cone differential pressure flow meter

What it is: A differential pressure flow meter for liquid, gas and steam. A cone centered in the pipe reshapes the velocity profile, so the meter is self-conditioning and tolerates disturbed flow. McCrometer introduced the V-Cone in 1985 and reports more than 75,000 installed.

Performance (from McCrometer specification sheets):

  • Accuracy: up to ±0.5% of rate
  • Repeatability: ±0.1%
  • Turndown: 10:1
  • Standard beta ratios: 0.45 to 0.85
  • Straight run: typically 0 to 3 pipe diameters upstream and 0 to 1 diameter downstream. Vertical upflow installations require wall pressure ports.
  • Actual performance is set by McCrometer's sizing for the application and by the secondary instruments used.

Line sizes: The weld-neck specification sheet covers 1/2 in. to 24 in.; the threaded-end specification sheet covers 1/2 in. to 6 in.; the part number configurator lists sizes to 60 in., with larger sizes available from the factory.

Pressure and temperature: Ratings follow the end connection class and material selected during sizing.

Materials offered: 304/304L and 316/316L stainless; 304H and 316H; carbon steel or low-temperature carbon steel body with stainless cone; duplex (S31803) and super duplex (S32760); Hastelloy C276; P11 and P22 chrome-moly; X52/F52 and X60/F60; Monel 400; Inconel 625; titanium.

End connections: slip-on, raised-face weld neck, RTJ weld neck, beveled, NPT threaded, plain end, Victaulic grooved, hub, DIN and JIS flanges, ASME classes 150 through 2500, API 6A 5000 and 10000 RTJ, and B16.47 A/B. Standard pressure taps are 1/2 in. 3000# NPT or socket; flanged taps and an RTD port are optional.

Fabrication and certifications: Manufactured under ISO 9001:2015. Welders and procedures qualified to ASME Section IX; welding per ASME Section VIII, B31.1 or B31.3. Testing options include hydrostatic, dye penetrant, radiographic, PMI and magnetic particle. Configurator options include PED Category II/III, NORSOK M630/M601 and NACE MR0103.

Typical fluids and applications: saturated and superheated steam, natural gas, wet and sour gas, fuel gas, digester gas, compressor discharge and surge control, cooling water, chemicals, crude oil and liquid hydrocarbons, CO2 injection, HVAC chilled water and steam, and boiler fuel. GGC also applies the V-Cone to landfill gas.

Source: mccrometer.com/product/v-cone ; V-Cone threaded-end specification sheet (VT_Threaded_Ends_Specification_Sheet.pdf) ; V-Cone weld-neck specification sheet (VWL_ANSI_B16.5_Weld_Neck_Specification_Sheet.pdf) ; V-Cone part number configurator (V-Cone_Part_Number_Configurator.pdf)

Wafer-Cone (Model VH)

What it is: A flangeless, wafer-style cone meter using V-Cone principles for gas and liquid flow. Cone elements are interchangeable to change the flow range.

Specifications (specification sheet 24509-51 Rev 2.8):

  • Sizes: 1, 1-1/2, 2, 2-1/2, 3, 4 and 6 in.
  • Accuracy: ±1.0% of rate; repeatability ±0.1%; turndown 10:1
  • Beta ratios: 0.45 to 0.85
  • Straight run: 1 to 3 diameters upstream, 1 diameter downstream
  • Design limits: 1500 psig (103 bar); -50 to 600 °F (-46 to 315 °C). Contact the factory for other limits.
  • Material: 316L stainless; plastic available in 1 to 3 in. only
  • Fits between ASME Class 150 through 2500, DIN and JIS 10K flanges. A centering device ships with each meter.
  • Optional gas or oil flow calibration

Source: mccrometer.com/product/wafer-cone ; VH_Wafer_Style_Specification_Sheet.pdf

Ultra Mag 3000 and 5000 (full-bore electromagnetic)

What it is: A full-bore electromagnetic flow meter with no flow obstruction and no moving parts. Measures bidirectional flow of conductive liquids, slurries and sludges.

Specifications (specification sheet 30125-98 Rev 1.2):

  • Sizes: Ultra Mag 3000, 1.5 to 24 in.; Ultra Mag 5000, 1.5 to 48 in.
  • Accuracy per the specification sheet: Ultra Mag 3000, ±1.0% of reading ±0.006 ft/s; Ultra Mag 5000, ±0.5% standard with ±0.2% optional.
  • Repeatability: ±0.05% or ±0.0008 ft/s, whichever is greater
  • Velocity range: 0.2 to 32 ft/s
  • Minimum conductivity: 5 µS/cm
  • Liner: UltraLiner fusion-bonded epoxy, NSF approved
  • Electrodes: 316 stainless standard, Hastelloy optional; 316 stainless grounding rings
  • End connections: AWWA Class D (standard) and Class F; ASME Class 150 and 300; wafer style in 2 and 3 in.
  • Straight run per the specification sheet: Ultra Mag 5000 (4 to 48 in.) 1 diameter upstream and 0 downstream; Ultra Mag 3000 (4 to 24 in.) 2 upstream and 1 downstream; 1.5 to 3 in. sizes need none
  • Transmitters: Ultra Mag 3000 uses the ProComm GO (battery standard, AC, DC or solar options; pulse, isolated 4-20 mA, Modbus). Ultra Mag 5000 uses the ProComm Max (AC or DC; 4-20 mA, HART, Modbus RTU and TCP, datalogger).
  • Enclosures: transmitter IP67; sensor IP68 / NEMA 6P
  • Certifications: ISO 9001:2015; NSF/ANSI 61 and 372; UL/CSA 61010-1; hazardous-location (HL) model rated Class I Division 2 Groups A to D (confirm temperature code with McCrometer); CRN option for 4 to 12 in. ANSI; CE
  • Warranty: 2 years

Typical applications: raw water, industrial cooling and process water, effluent and activated sludge.

Source: mccrometer.com/product/ultra-mag-3000 ; Ultra_Mag_Specification_Sheet_30125-98r12.pdf

FPI Mag 3000 and 5000 (full-profile insertion electromagnetic)

What it is: A multi-electrode electromagnetic insertion probe that measures across the full pipe profile. It installs by hot tap, with no shutdown, dewatering or pipe cutting. McCrometer states it is intended for clean water applications.

Specifications (specification sheet 30127-04 Rev 1.2):

  • Pipe sizes: standard models 4 to 24 in.; custom models 4 to 138 in.
  • Accuracy: FPI Mag 3000, ±1% of reading ±0.006 ft/s; FPI Mag 5000, ±0.5% of reading ±0.006 ft/s
  • Repeatability: 0.2% of reading; linearity 0.3% of range
  • Velocity: 0.5 to 32 ft/s on smaller lines, narrowing on the largest sizes
  • Maximum operating pressure: 250 psi
  • Temperature: coating rated to 140 °F; HT option to 200 °F
  • Materials: 316 stainless body and electrodes (Hastelloy electrodes optional); NSF-61 fusion-bonded epoxy coating; 2 in. stainless ball valve and nipple included
  • Certifications: ISO 9001:2015; NSF/ANSI; UL 61010-1; HL option rated Class I Division 2 Groups A to D and Class I Zone 2 IIC
  • Ordering needs: pipe ID and OD, units, maximum pressure, and a specification data sheet for custom-length sensors. Consult the factory if chemicals are present.

Typical applications: campus and central plant chilled water mains, cooling and condenser water, process water, feed water and effluent.

Source: mccrometer.com/product/fpi-mag-3000 ; 30127-04_FPI_Mag_Spec_Sheet_Rev_12.pdf

SPI Mag 3000 and 5000 (single-point insertion electromagnetic)

What it is: An insertion mag installed by hot tap through a ball valve or corporation stop, measuring at a single point near the pipe wall.

Specifications (specification sheet 30126-39 Rev 1.1):

  • Pipe ID: 2 to 96 in. (1 in. sensor for 2 to 30 in. pipe; 2 in. sensor for 6 to 96 in. pipe)
  • Accuracy: ±2% of measured value ±0.03 ft/s
  • Velocity: 0.3 to 32 ft/s
  • Ratings: PVC insertion tube 105 °F at 150 psi; stainless tube (recommended) 160 °F at 250 psi
  • Wetted materials: polyurethane sensor, PVC or stainless mounting, Buna-N O-ring
  • Fluids: cooling water, wastewater, slurries, sludge, pulp stock

Source: mccrometer.com/product/spi-mag-3000 ; 30126-39_SPI_Mag_Spec_Sheet_Rev_1_1.pdf

McPropeller (industrial propeller meters)

What it is: A mechanical propeller meter with straightening vanes and a magnetically coupled register. It needs no external power.

Specifications (McPropeller brochure for industrial applications):

  • Line sizes: 2 to 96 in. and larger
  • Accuracy: ±2% of reading over the full range; ±1% over a reduced range
  • Repeatability: 0.25% or better; range up to 25:1
  • Temperature: 160 °F constant maximum; high-temperature impeller optional
  • Models: QW500 (all stainless, 2 to 24 in., 150 psi), QZ500 (all stainless, 2 to 20 in., 300 psi), MW500 (carbon steel, 2 to 36 in., 150 psi), MZ500 (carbon steel, 2 to 24 in., 300 psi)
  • Materials: epoxy-coated carbon steel or all-stainless body; plastic impeller; 316 stainless shaft; 440C bearings
  • Registers: mechanical, FlowCom digital, FlowConnect wireless
  • Complies with AWWA C704-08
  • Applications: industrial water treatment, fire water, wash-down, chemical injection, fuel oils

Source: mccrometer.com/product/mcpropeller ; McPropeller_Brochure_for_Industrial_Applications_30126-82r12.pdf

What to send GGC for sizing or a quote

For a V-Cone or Wafer-Cone:

  • Fluid and its properties (density or specific gravity, viscosity); for gas, also molecular weight or composition, compressibility, isentropic exponent and base conditions
  • Minimum, normal and maximum flow
  • Operating pressure and temperature, plus design pressure and temperature
  • Line size, pipe schedule and pipe material
  • End connection type and flange class
  • Allowable permanent pressure loss
  • Orientation (horizontal, vertical up or down) and available straight run
  • Tap configuration and whether a multivariable or DP transmitter is wanted
  • Required material certifications, NACE or PED requirements, and hazardous area classification

For an electromagnetic meter (Ultra Mag, FPI Mag, SPI Mag):

  • Liquid and its conductivity; solids content if any
  • Minimum, normal and maximum flow
  • Pipe material, ID and OD (and wall condition for insertion meters)
  • Operating and maximum pressure and temperature
  • Whether the line can be shut down (full bore) or must stay in service (hot tap insertion)
  • Available power (AC, DC, battery or solar) and the outputs needed (4-20 mA, pulse, HART, Modbus)
  • Hazardous area classification and any NSF requirement

For landfill gas and RNG: mass flow needs pressure, temperature and gas composition, usually through a multivariable transmitter on a V-Cone. Include expected moisture and contaminants.

Common questions

Can a V-Cone go right after an elbow?

Usually. McCrometer states typical straight-run requirements of 0 to 3 diameters upstream and 0 to 1 downstream. Final placement is confirmed in sizing.

Does the V-Cone need periodic recalibration?

McCrometer states the V-Cone does not need recalibration.

Can I measure a chilled water main without shutting it down?

Yes. The FPI Mag installs by hot tap through a valve on the live line.

Will a mag meter work on steam, gas or oil?

No. Electromagnetic meters need a conductive liquid of at least 5 µS/cm. Use a V-Cone for steam, gas and hydrocarbons.

Does GGC handle municipal water projects for McCrometer?

No. GGC represents McCrometer for industrial and oil and gas applications, including landfill gas and RNG. McCrometer serves municipal water and wastewater through separate representatives.

GGC application experience

  • A Tennessee EV manufacturing campus central utility plant standardized on more than 100 McCrometer meters.
  • A Tennessee AI data center uses three McCrometer technologies for cooling and utility flow measurement.

Sources

All engineering references